FIELD OF APPLICATION:
APPLICATION ON
BATHROOM/TOILETS: APPLICATION ON DOOR /WINDOW/ALUMINUM SECTION: The gap between the wooden frames (door/windows) or Aluminum section and the cement surface can be bridged with readymade putty “DIBHALITE-SLF”. his will prevent the water penetration to the room. APPLCATION ON DAMP SURFACES: (Flooring & walls) We recommend “DP-250” as an primer coat, which being Waterbased Epoxy Resins system shall take care of dampness or moistures presents in the concrete surfaces. For more strength, cracks, even level of surface - Epoxy putty “Dl-SLF” shall be coated with min.2 mm thickness. APPLICATION TO FILL CRACKS: Cracks and void developed on terraces/water tanks/building structures can be successfully filled in by applying prime coat of DP-250 in the crack and after two hours the joints/voids can be bridged with DIBHALITE -SLF. APPLICATION TO TREAT EFFLORESENCES/LATENCES:
1.
Clean
the surface with wire brush to remove effloresces and latencies. Wash
the entire surface with
2.
On
curing of prime coat (after 2 - 3 hrs.) apply 2mm thick putty of DL-SLF
and when dried, paint the APPLICATION ON ASBESTOS SHEET: On the joints/cracks of asbestos sheet, directly apply DIBHALITE -SLF .Moreover, on the junction (i.e. the asbestos sheet and the building structure) apply one coat of DP -250.On curing of primer apply DIBHALITE -SLF with min.2 mm thickness, which shall fill up the cracks. PRECAUTION: Mix only the required quantity of DP-250 and DL-SLF, which can be utilize within stipulated pot-life period to avoid solidification. Wash all tools and tackles with ample of water immediately after application is completed WATERPROOFING OF DAMP WALLS BY DP-250 & DL-SLF Dibhapoxy-250 & Dibhalite-SLF is an Waterbased Epoxy Resin system and is two pack components (i.e. Resin and Hardener ), wherein “DP-250 “ is to be treated as primecoat as it has brushable consistency and “DL-SLF “ as putty as loaded with required fillers to stop the dampness of internal walls . Moreover, our technical information’s and recommendations contained here in are based on reliable test and accepted to be ultimate solutions to any raising dampness of masonry surfaces (walls).
1.
Remove
the old existing layers of paint to the original laser surface by
chipping and clean the loose
2.
If on
plaster the cracks are seen by naked eyes than shape the same in “
V “ shape by proper
3.
Mix “ DP-250 “ both the parts in equal proportions by volume by giving
stirring for 2 - 3
4.
On
curing of prime coat , mix “DL-SLF “ with equal proportions and apply
the same on entire surfaces 5 On complete curing of the system cited above , normal painting can be carried out. Here the first coat shall give adequate bond in between Plaster and “DL-SLF “ shall fill up the cavity of small hair cracks alongwith even level of surface. Moreover “DP-250 “ shall cover 50 - 60 sq.ft. per single coat and “DL-SLF “ shall cover 25 - 30 sq.ft. per 1.5 - 2.0 mm thickness. For furthermore information’s please contact the manufacturers. |
|||||||||||||||||||||||||
![]() |
|||||||||||||||||||||||||
|